ZXHQ-C transformer calibrator is a new kind of automatic testing instrument. It uses electronic technology to directly decompose the error signal of the transformer, and after proper calculation, the percentage point, in-phase error and orthogonal error of the transformer are displayed in digital quantity at the same time. The instrument has the advantages of simple operation, direct reading, rapid measurement, low power consumption and labor intensity, small volume, light weight, easy carrying and field test, and can be tested under 5% rated working current (voltage).

Features
Technical indicators

Useenvironment:

1. Temperature: 5 ℃ -- 40 ℃ relative humidity: < 80% (25 ℃) altitude: < 2500m

Power frequency: 50Hz ± 0.5Hz power voltage: 220V ± 5V

2. Measurement range:

In phase component (%): 0.0001 ~ 200.0 resolution: 0.0001

Orthogonal component (min): 0.001-700.0 resolution: 0.001

Impedance (Ω): 0.0001 ~ 20.0 resolution: 0.0001

Mobility (MS): 0.0001 ~ 20.0 resolution: 0.0001

3. Basic error:

In phase component: Δ x = ± (x × 2% + y × 2%) ± DX (with level 1 option)

Orthogonal component: Δ y = ± (x × 2% + y × 2% × 34.48) (Level 1 optional)

"X", "Y" - display value of the instrument

"DX, Dy" - quantization error of instrument Dx = 2, Dy = 5

4. Dial indicator: level 1.5 (optional level 1)

Scope of work:

1. Current: (1% - 149%) in (in = 5a)

(5%-149%)In(In =1A)

2. Voltage: (5% - 149%) UN (UN = 100V, 150V, 100V / √ 3)

(5%-149%)Un(Un =100V/3)

Workload:

1. Current: TO to TX < 0.12Ω cos Φ = 1

2. Voltage: A to X < 0.25va (100V)

5. Power consumption: < 15va (without micro printer)

< 25VA (with micro printer)

6. Harmonic suppression ratio: > 40dB

7. Boundary dimension: 260 × 350 × 150 mm

8. Weight: 6kg