ZXDN-3B Intelligent Energy Meter Calibrator
This instrument is a superior product in the company's electric energy measurement series, which integrates an electric energy meter calibrator and a low-voltage metering device calibrator. It has the functions of electric energy meter error checking, wrong wiring judgment, transformation ratio measurement, meter reading, harmonic measurement, etc.
1. A high brightness, high definition and high resolution TFT color LCD screen shows clearly and beautifully, with large information content and rich content, and the screen shows all the parameters measured on the site.
2. Single and three phase voltage, current, power, phase, active and reactive power factor, frequency and other parameters can be in real time measured.
3. The energy meter and terminal errors can be calibrated, and single-phase and three-phase electronic induction active and reactive energy meters can be inspected.
4. The pulse input modes include manual input, photoelectric input and electric pulse input three ways.
5. 100A, 500A and 1000A clamp meters are optional, and the transformation ratio of low voltage current transformer is directly measured; it is easy to find the open circuit and poor contact in the CT secondary circuit, internal turn-to-turn short circuit of CT and whether the transformation ratio on the CT nameplate is consistent with the actual transformation ratio of CT.
6. It can measure the content of the 2nd ~ 51st harmonics of single and three phase voltage and current.
7. The waveforms of A, B and C-phase voltage and current can be measured.
8. A wide range of working power supply is AC57 ~ 450V; the test line, adapter and battery power supply can be chosen respectively, and online charging is available.
9. With a large capacity memory card, it can store field calibration data of more than 10000 groups of energy meters, and U disk storage is supported; such data can be permanently saved upon non-human deletion
10. The ground software system can connect with the marketing system, with a friendly interface, easy operation, complete functions and easy to upgrade; the test data cannot be changed, and the software has the functions such as statistics, query, and printing; the test report format can be set according to the requirements of users.
11. Read the record data of multi-function electronic energy meter including the reading data, pressure loss records and clock.
12. The calibrator has the function of clamp transformer self-correction and NO need to return to factory for calibration after replacing the clamp meter.
13. Clock error calibration;
14. Broadcasting timing or command timing of the energy meter can be done ( subject to the calibrator time);
15. The rate and time period of the energy meter, demand register and others, and demand value error can be read and set.
16. With the function of small current detection, it is convenient for initial installation and no-load line inspection.
17. Support for bar codes and 2D code scanning input, and an external barcode scanner (USB or wireless way) can read the meter asset number and seal number, etc., convenient for field entry;(optional)
18. With bluetooth, WIFI and GPS interface for options
Voltage range |
AC 40-440V |
||
Current range (double overload) |
Terminal input |
5A, 1A |
|
Clamp meter input |
5A 20A 100A 500A 1000A 1500A |
||
Grade |
5A Terminal, 1A Terminal |
0.05 |
|
5A clamp(With the function of self-correction), 20A clamp |
0.2 |
||
100A, 500A and 1000A |
0.5 |
||
Power pulse constant |
5A Terminal, 1A Terminal, 20A clamp, 5A clamp,100A clamp, 500A clamp and 1000A clamp |
FL=36000P/kWh FH=3.6×108 P/kWh |
|
Frequency |
45-65Hz |
||
Phase measurement range |
-180 -- +180 degrees |
||
Transformation ratio of Transformer |
< ±0.5% |
||
Voltage influence |
< ±0.01% |
||
Frequency influence |
< ±0.01%(45-65Hz) |
||
Temperature influence |
< ±5ppm/℃ |
||
24h deviation |
(0.1)< ±0.02% (0.05)< ±0.01% |
||
Basic errors |
U.I Harmonic measurement |
||
Terminal input |
Measuring range |
2nd-51st harmonics |
|
Active power |
±0.1% ±0.05% |
Accuracy of measurement |
±0.01%(relative to 100% fundamental wave) |
Reactive power |
±0.1% |
Other technical indicators |
|
Power |
±0.1% ±0.05% |
Switching power supply |
AC57.7~440V(45~65Hz) |
Voltage |
±0.1% ±0.05% |
Power consumption |
About 6VA |
Current |
±0.1% ±0.05% |
Environment temperature |
-20`C--+40`C(Guaranteed accuracy) |
Frequency |
±0.05Hz |
Relative humidity |
40%-95% No condensation |
Phase |
±0.1 degree ±0.05% degree |
Warm-up time |
< 3min |
Weight |
1.8kg |
Overall dimensions |
(L)249*(W)154*(H)58mm |
-
Pre-sale service commitments
-
Sale service commitments
-
Sale service commitments