ETCR Series Earth Clamp Meter

ETCR series Earth Clamp Meter is widely used in the grounding resistance measurement of electric power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment.

The measurement does not require disconnecting the grounding wire, need no auxiliary electrode. It is safe, fast and simple in use. It equips long jaws or round jaws. Long jaw is particularly suitable for the occasion of grounding with the flat steel. It also be able to measure the leakage current and the neutral current in the grounding system.


Features
Technical indicators
Model Jaws size Resistance range Current range Data upload Alarm Data save
ETCR2000A Long type 65×32mm 0.01Ω-200Ω × × × ×
ETCR2000 0.01Ω-1000Ω × × × ×
ETCR2000C 0.01Ω-1000Ω 0.00mA-20.0A ×
ETCR2000A+ 0.01Ω-200Ω × ×/√
ETCR2000+ 0.01Ω-1200Ω × ×/√
ETCR2000B+ 0.01Ω-1200Ω × ×/√
ETCR2000C+ 0.01Ω-1200Ω 0.00mA-20.0A ×/√
ETCR2000E+ 0.01Ω-1200Ω 0.00mA-40.0A
ETCR2100A Round type32mm 0.01Ω-200Ω × × × ×
ETCR2100 0.01Ω-1000Ω × × × ×
ETCR2100C 0.01Ω-1000Ω 0.00mA-20.0A ×
ETCR2100A+ 0.01Ω-200Ω × ×/√
ETCR2100+ 0.01Ω-1200Ω × ×/√
ETCR2100C+ 0.01Ω-1200Ω 0.00mA-20.0A ×/√
ETCR2100E+ 0.01Ω-1200Ω 0.00mA-40.0A
Function Ground resistance test, contact resistance test
Resistance accuracy max ±1%±0.01Ω
Current accuracy max ±2.5%±1mA
Power Supply 6VDC 4 PCS of AA Alkaline batteries
*Alarm Threshold Setting Range* Resistance: 1-199Ω * C type only
Alarm Sound and Light "Beep-beep-beep" alarm tone, Alarm Symbol Flashing, Press AL key to turn on,
turn off Alarm or set Alarm Threshold.
Interference Signal Recognition "Beep-beep-beep" tone, NOISE symbol blinking
Working Temperature and Humidity -20°c-55°c; 20%RH-90%RH
LCD Screen 4 Digits LCD display, Screen L*W: 47mm*28.5mm
Clamp Opening Extent 32mm
Tester Weight < 2KG
Protection Level Dual Insulation
Structural Feature Clamp CT
range Shifting Automatic shifting
External magnetic field <40A/m
External electrical field <1V/m
Single measurement time <1 second
Resistance measurement frequency >1KHz
Measured current frequency 50/60Hz Automatic measurement
Low Battery Indication Low battery symbol displays when battery is lower then 5.3V
Memory Full Indication MEM symbol blinks when all 99 sets memory is full
Over Range Indication Out of range indication "OLΩ”, "L0.01" or "OL A"
Auto Power-off 5 minutes after Boot up
Power Consumption Max 50mA either in booting up or normally working, Continuously working for 30 hours
RS232 Interface (Optional) The data stored in the meter are uploaded to the computer through RS232 interface and data wire, Then generate report files
Accessories Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece, Manual 1 Copy